HanYoung Nux GE Counters
GE

GE Counters Description

The GE series controllers can perform as a counter or timer (User configurable). They offer users high functionality in both input and output control methods.

Specification

Model GE4 GE6 GE3 GE7
Power
voltage
a.c 100 - 240 V a.c ( 50 - 60 Hz ) ± 10 %
d.c 24 - 60 V d.c / a.c ( 50 - 60 Hz ) ± 10 %
Power
consumption
a.c Max. 13.5 V a.c
d.c Max. 9 V A
FND height 11 mm 13 mm
8 mm 10 mm
Counting speed and input 1 cps / 30 cps / 1 K cps / 10 K cps, Contact / Non - contact
Memory for power failure 10 years ( Nonvolatile memory)
Input CP1, CP2, RESET, BATCH RESET (exclude TOTAL) 4 inputs
[H] level 4-30 V d.c, [L] level 0-2 V d.c, Internal pull - up / pull - down
resistance connection due to NPN / PNP setup
Min. input signal Counter External reset Min. input signal range : select among 0.1 ms / 1 ms / 20 ms
Timer START, INHIBIT, RESET Min. input signal range : select either 1 ms / 20 ms
External output
power
a.c 12 V d.c(± 5 %) 200 mA Max
d.c 12 V d.c(± 5 %) 100 mA Max
ONE SHOT output 0.01 - 99.99s [OUT1, OUT2 (OUT)]
Control
output
contact 1 step 1c (OUT) 1a (OUT) 1c (OUT)
2 step 1c (OUT1), 1c (OUT2)
Capacity NO contact : 250 V a.c 3 A resistance load, NC contact : 250 V a.c 2 A resistance load
Non
contact
1 step NPN 2 points (OUT, BAT.O)
2 step - - NPN 2 points (OUT1, OUT2)
Capacity Open collector 30 V d.c 100 mA Max.
Timer operation Comparative cycle : repeated setup error less than 5 ms for every 2 ms
Stable time : 100 ms stable time when POWER ON
Dielectric Strength 2000 V a.c 50 - 60 Hz for 1 minute
Insulation Resistance Min. 100 MΩ (Based on 500 V d.c)
Withstand noise Squard wave noise by noise simulator (1μs pulse per each 16 ms) ±2 kV (Power supply input terminal)
Vibration Malfunction 10 - 55 Hz (for 1 minute) double amplitude 0.5 mm X. Y. Z each direction for 10 minutes
Durability 10 - 55 Hz (for 1 minute) double amplitude 0.5 mm X. Y. Z each direction for 2 hours
Shock Malfunction 100 m/s² (About 10 G)
Durability 300 m/s² (About 30 G)
Relay Life Electrical Min. 100 thousand times (250 V a.c 2 A resistance load)
Mechanical Min. 1 millions times
Protection structure IP65 (Front part only)
Ambient temperature -20 ~ 65 °C (None freezing state)
Ambient humidity -10 ~ 55 °C, 35 ~ 85 % R.H. (No freezing of decondensation)
Weight Max. 133 g Max. 138 g Max. 203 g
Certificate CE

Model Description
GE Digital Batch Counter
Appearance GE3 96(W) x 48(H) x 107.6(D) mm
GE4 48(W) x 48(H) x 79.3(D) mm
GE6 72(W) x 36(H) x 81(D) mm
GE7 72(W) x 72(H) x 87(D) mm
Type P PRESET, BATCH
T TOTAL (Indicator)
Digit 4 4 : 9999 (4 digit) *GE3, GE7 : Not available
6 6 : 999999 (6 digit)
Stage 1 1 stage
2 2 stage * Twin timer Support
Power supply A 100 V - 240 V a.c
D 24 V - 60 V d.c